Panarc Recessed luminaires
Downlights
- System overview
- | Product overview
- | Accessories

Wide beam, rotationally symmetrical light distribution for general lighting.
Lighting technology

Downlights with flood lens or diffuser
2xTC-S lamp
2xTC-L lamp
1xTC-F lamp
Luminaire arrangement

The arrangement of Panarc luminaires depends primarily on the design criteria.
A regular grid is recommended for uniform, horizontal illumination.
The guide value for the grid size (d) is the luminaire height (h) above the working plane.
The offset of the luminaire from the wall (a) is recommended to be half the module of the grid (d).

Double washlights
- System overview
- | Product overview
- | Accessories

Axially symmetrical light distribution, directed downwards, combined with illumination of parallel walls for corridors and hallways.
Lighting technology

2xTC-S lamp
2xTC-L lamp
1xTC-F lamp
Luminaire arrangement

Position the luminaires on the centre line between the walls for double wallwashing.
Luminaire spacing (d) equal to the offset from wall (a) for uniform washlighting, align the lens structure parallel to the plane of the walls


Position the luminaire on the wall at eye-level for floor-ceiling washlighting
Luminaire spacing (d) equal to the ceiling height or at eye-level h for uniform washlighting
Align the lens structure parallel to the plane of the floor-ceiling