Arrangement of downlights depends on the design criteria.

A regular grid is recommended for uniform, horizontal illumination.

The guide value for the grid size (d) is the luminaire height (h) above the working plane.

The offset of the luminaire from the wall (a) is recommended to be half the module of the grid (d).


ERCO
Lens wallwashers
ERCO
Offset from wall a: intersection of the 20° line with the ceiling plane

Luminaire spacing (d) equal to the offset from wall (a) for uniform wallwashing.

Lower luminaire spacing in high room

ERCO
Directional luminaires
ERCO
Angle of tilt 20° for lighting vertical objects.