Surface-mounted downlights


Wide beam, rotationally symmetrical light distribution for general lighting.


Lighting technology

2xTC-SEL lamp
2xTC-L lamp
TC-F lamp


Luminaire arrangement

The arrangement of Panarc luminaires depends primarily on the design criteria.

A regular grid is recommended for uniform, horizontal illumination.

The guide value for the grid size (d) is the luminaire height (h) above the working plane.

The offset of the luminaire from the wall (a) is recommended to be half the module of the grid (d), or one third of the room height (h).



Surface-mounted double washlights


Axially symmetrical light distribution, directed downwards, combined with illumination of parallel walls for corridors and hallways.


Lighting technology

2xTC-SEL lamp
2xTC-L lamp
TC-F lamp


Luminaire arrangement

Position the luminaires on the centre line between the walls for double wallwashing.
Luminaire spacing (d) equal to the offset from wall (a) for uniform washlighting.
Align the lens structure parallel to the plane of the wall.


Position the luminaire on the wall at eye-level for floor-ceiling washlighting.
Luminaire spacing (d) equal to the ceiling height or floor (h) for uniform floodlighting,
align the lens structure parallel to the plane of the floor-ceiling.


back