Program Outdoor
Tesis In-ground luminaires IP68
Recessed floor luminaires square | Recessed floor luminaires round 
Recessed floor luminaires square
ERCO
Focus wallwashers
Offset from wall: one third of the wall height

a = h/3 to a = h/2
ERCO
Luminaire spacing up to 1.5x offset from wall

d = 1.5a

Distance to wall: half the luminaire spacing

c = d/2
ERCO
Lens wallwashers
Offset from wall: one third of the wall height

a = h/3
ERCO
Luminaire spacing up to 1.25x offset from wall

d = 1.25a

Distance to wall: half the luminaire spacing

c = d/2
ERCO
Wallwashers
Offset from wall: one third of the wall height

a = h/2
ERCO
Luminaire spacing up to 1.25x offset from wall

d = 1.5a

Distance to wall: half the luminaire spacing

c = d/2
ERCO
Directional luminaires
Maximum distance to the base of object: one third of the object's height

a = h/3

For wallwashing with sculpture lens: for offset from wall select one third of the ceiling height

a = h/3

Luminaire spacing up to 1.5x offset from wall

d = 1.5a

Distance to wall: half the luminaire spacing

c = d/2
ERCO
In-ground luminaires
For visual guidance on the ground
ERCO
Luminaire spacing approx. 2x offset from wall

d = 2a

Distance to wall: half the luminaire spacing

c = d/2
Recessed floor luminaires round
ERCO
Adjustable uplights for a grazing-light effect: offset from wall up to one sixth of the height of the projected beam

a = h/6
ERCO
Luminaire spacing: to suit the design intention

c = d/2
ERCO
Luminaire spacing: as specified, e.g. to suit column spacing
ERCO
Uplights
Arrangement to suit the design intention or specifications
ERCO
Lens wallwashers
Offset from wall: one third of the wall height

a = h/3
ERCO
Luminaire spacing up to 1.5x offset from wall

d = 1.5a

Distance to wall: half the luminaire spacing

c = d/2
ERCO
Directional luminaires
Maximum distance to the base of object: one third of the object's height

a = h/3

For wallwashing with sculpture lens: for offset from wall select one third of the ceiling height

a = h/3

Luminaire spacing up to 1.5x offset from wall

d = 1.5a

Distance to wall: half the luminaire spacing

c = d/2
ERCO
In-ground luminaires
For visual guidance on the ground
ERCO
Luminaire spacing approx. 2x offset from wall

d = 2a

Distance to wall: half the luminaire spacing

c = d/2
back
Product characteristics
Introduction
Product images
System overview
Lighting technology
Luminaire arrangement
Pictures of application
Accessories
Colour compensated LED luminaires
Reflector technology

Print product characteristics (.pdf)

Product overview
Specification sheets and planning data

Context
Projects
Guide

Bookmark this page