ERCO wants to offer you the best possible service. This website stores cookies for this purpose. By continuing to use this website, you consent to the use of cookies. For more information, please read our privacy policy. If you click on "Do not agree", essential cookies will continue to be set. Certain contents of external pages can no longer be displayed.

Luminaire spacing in general lighting

Advantages of differentiated light distributions

Reducing lighting costs and installation costs

In addition to energy and maintenance costs, the initial investment in a lighting system is decisive for construction authorities. This includes costs for individual luminaires as well as electrical installation and mounting. Installation costs are reduced if fewer luminaires are needed. To continue complying with minimum normative requirements such as uniformity and nominal illuminance using a reduced quantity of luminaires, differentiated light distributions are needed. As a consequence, oval light distributions for example allow wide luminaire spacing and therefore the sufficient illumination of corridors. For this purpose the lens system spreads the light distribution more strongly in one direction than in the other.

Luminaire spacing in general lighting

ERCO downlights with oval flood light distribution

Up to 40% less luminaires due to differentiated light distribution (product data from 2017)

Luminaires:4
Nominal illuminance (lx):150
Connected load (W/m²):3,01

Luminaire spacing in general lighting

Standard downlights with wide light distribution

More luminaires and up to 33% higher energy consumption with generic light distribution (product data from 2017)

Luminaires:7
Nominal illuminance (lx):154
Connected load (W/m²): 4,47

ERCO Newsletter - inspiring projects, new products and fresh lighting knowledge

Subscribe to the newsletter
Your data will be handled confidentially. For further information see Data protection declaration
From now on, for convenience and speed, we will be emailing the ERCO Newsletter in a digital format on a regular basis to help you keep up with the latest news from ERCO. We aim to ensure that you’re updated about events, awards, fresh lighting knowledge, project reports and product news along with reports from the lighting and architectural sectors. The publication is free and you can unsubscribe at any time.