Light impact and luminaire arrangements

Light for large surfaces: room height 3-5m

General lighting

Large rooms with heights of 3-5m benefit from economical general lighting with downlights that combine extra wide light distributions with good glare control. Extra wide flood light distribution has the advantage that fewer luminaires are needed because of wide spacing between the luminaires. At the same time, these downlights feature high vertical illuminances to facilitate the recognition of faces – this is important for a communicative atmosphere in rooms where many people come together.

Luminaire arrangement with extra wide flood light distribution

The following rule of thumb applies for arranging luminaires with extra wide flood light distribution: the luminaire spacing (d) should be equal to or less than 1.5 times the height of the luminaires above the working plane (h). d ≤ 1.5 x h