Light impact and luminaire arrangements
Lighting office workplaces
Good facial illumination and uniform general lighting increase visual comfort at office workplaces.
Zoning work areas with low glare using oval wide flood
Luminaires with oval wide flood distribution not only provide long desks with high horizontal illuminance, but also provide high vertical illuminance for good facial clarity. Simultaneously, good glare control (UGR<19) in the direction of the user increases visual comfort. Added value of oval wide flood light distribution: - efficient, uniform office workplace lighting - good facial illumination
Rule of thumb for arranging oval wide flood light distributions
To achieve high uniformity and good facial lucency when illuminating office workplaces, the luminaire spacing of downlights with oval wide flood light distribution (d) can be up to 1.5 times the height (h) of the luminaire above the working plane. Arrangement: d ≤ 1.5 x h Tip for luminaire selection: With axially symmetrical light distributions such as oval white flood the correct alignment of the luminaire should be noted in the design.
Avoiding reflected glare
To avoid reflected glare and improve modelling, the luminaire should not be directly above the office workstation. This minimises reflected glare on keyboards or glossy documents.